Machines affected |
All machines with Firmware 0 or Firmware 1. |
||
Component |
UDRC, Pressure sensor, Lionel Board - POC Start, PACC Start |
||
Error |
27024/43024: Unable to calibrate |
||
Cause |
|
||
Solution |
Cause 1: NVS parameters may be incorrect.
Cause 2: The zero pressure value for the sensor is not close enough to zero. The line may be plugged and under vacuum or the sensor may be defective.
Note: The bellmouth sensor is the 0-100" scale Setra brand sensor. The differential sensor is the 0-10" scale. Cause 3: On systems equipped with a Setra nozzle sensor, the control lines to the nozzle sensor may have touched together while energized. This will damage a diode on the Lionel board, causing the sensor to display half its value. This value will be greater than +-5% from the anticipated 0 value and will not permit calibration.
|
||