Timeout: the pressure sensor output failed to stabilize (error #27026/43026)


Product

 
  • Platesetter 3244
  • ThermoFlex
  • Trendsetter 400/800
  • Trendsetter Autoloader
  • Trendsetter NEWS
  • Trendsetter Spectrum
  • Trendsetter VLF
  • Trendsetter VLF Autoloader
  • VLF Platesetter

Machines affected

 

All machines with Firmware 0 or Firmware 1.


Component

 

UDRC, Pressure Sensor- POC Start, PACC Start


Error

 

27026/43026:  Timeout: the pressure sensor output failed to stabilize


Symptoms

 

 


Cause

 

With the blower off the system is checking the pressure sensor(s) to see if they are stable. The system thinks that the pressure is fluctuating, and can't determine a stable reading to set the offset.


Solution

 

  1. Unplug the sensing line(s) to the offending sensor.
  2. Reset the output device.
    • If the error is still present, then the sensor is defective and must be replaced.
    • If the error goes away, then the pressure really is unstable and the cause must be determined.
  3. If the nozzle sensor is unstable, try cleaning the nozzle (see cleaning instructions.)
  4. Reboot the device and try again.
  5. Replace the appropriate sensor.