Machines affected |
All machines with Firmware 0 or Firmware 1. |
||
Component |
UDRC (L-Configuration), Option Validation |
||
Error |
27029/43029: Command failed: cannot run more than one PACC option at a time |
||
Symptoms |
|
||
Cause |
You are currently running the debris system as either CTP or FLEXO and trying to set the system up for an additional process at the same time. |
||
Solution |
Reset the output device, then start the desired option. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
30 Sep 2003 |
||