Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Lid Leaks on Morgan Cabinets


Product

 
  • ThermoFlex
  • Trendsetter 400/800
  • Trendsetter NEWS
  • Trendsetter VLF
  • VLF Platesetter

Machines affected

 

All devices that use a Morgan Cabinet for debris removal


Component

 

Morgan debris removal cabinet


Symptoms

 

After the filter is replaced, vacuum begins to leak between the lid and the canister on Morgan debris removal cabinets.


Cause

 

The lid does not seal properly on the canister of the Morgan filtration unit (11-0594X-X).


Solution

 

The gasket on top of the replacement filter has been modified to allow the lid to completely compress it and fit snugly. The new gasket has an outside diameter of 285mm.

All new shipments of replacement filters (55-0691) will contain the new gasket. The new filters are marked on top with "G-285mm". See the photo below.

replacement filter with new 285mm O.D. gasket
Filtration unit for Morgan cabinet - PN 55-0691

Technical contact(s)
 

Michael Herbert

Submitted by
 

Michael Herbert

Date submitted
 

08 Nov 2002