Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
||
Machines affected |
All devices that use a Morgan Cabinet for debris removal |
||
Component |
Morgan debris removal cabinet |
||
Symptoms |
After the filter is replaced, vacuum begins to leak between the lid and the canister on Morgan debris removal cabinets. |
||
Cause |
The lid does not seal properly on the canister of the Morgan filtration unit (11-0594X-X). |
||
Solution |
The gasket on top of the replacement filter has been modified to allow the lid to completely compress it and fit snugly. The new gasket has an outside diameter of 285mm. All new shipments of replacement filters (55-0691) will contain the new gasket. The new filters are marked on top with "G-285mm". See the photo below.
|
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
08 Nov 2002 |
||