Component |
External Debris Removal Cabinet |
||
|
|
|||
Error |
"10064 - External debris blower not connected or filters
full - vacuum level 0 is below 5".
|
||
|
|
|||
Cause |
Cause 1: If the cabinet is turned on within 30 seconds of being turned off, the debris nozzle vacuum sensor may not calibrate correctly. As a result, the vacuum sensor readings are too low and the above error message is generated. This problem occurs most often when a new plot initiates immediately after the 10-minute automatic shut-off. Cause 2: A piece of the plastic wrap used to package the plates may have fallen on the floor and have been sucked into the debris removal cabinet's inlet for cooling the vacuum motor. |
||
|
|
|||
Solution |
Solutions to Cause 1
At some sites, the NVS settings for low stop, low warning, and high stop vacuum levels may have been changed to prevent the error message. If so, the settings should be restored. The standard settings for the one piece nozzle are:
Other settings that may have been disabled should also be restored:
Note: The next release of firmware will eliminate this calibration timing glitch. Solution to Cause 2: Remove the blockage from the cooling intake. |
||
|
|
|||