| element
| The element to stream from 0 to 6 ( Tfx )
|
|
| element
| The element to stream from 0 to 7 ( Thermal2 )
|
Enables / disables streaming of elements where each element consists of one or two A/D samples. If the element has two A/D samples, then the A/D conversion subsystem will stream the following information:
|
|
| <Counter>: <Sample #0>/<Sample #1>
|
|
| If the element has one A/D sample, then the A/D conversion subsystem will stream the following information:
|
|
| <Counter>: <Sample>
|
|
| The element counter displays the number of A/D samples that have been acquired for the element. Most of the elements are sampled at a pre-determined rate and this field can be used to determine the elapsed time between samples. This field is intended for data analysis.
|
|
| The A/D samples are twelve-bit numbers representing the sample data. The A/D conversion subsystem will display the numbers in hexadecimal and will not attempt to interpret the format of the sample data.
|
|
| This is intended as a development tool and should not be used during normal operation.
|
Thermal 1.0 / 1.7x equivalents:
|
|
|
- The monitor command adc stream (on <element>|off) does not have an equivalent.
|
COMMAND: adc info
|
|
|
ERRORCODE: [00102] The sample element is invalid
|