Tfx Command
(requires ENG access)
adc stream (on <element>|off)

Variables element The element to stream from 0 to 6 ( Tfx )
element The element to stream from 0 to 7 ( Thermal2 )

Description Enables / disables streaming of elements where each element consists of one or two A/D samples. If the element has two A/D samples, then the A/D conversion subsystem will stream the following information:

<Counter>: <Sample #0>/<Sample #1>

If the element has one A/D sample, then the A/D conversion subsystem will stream the following information:

<Counter>: <Sample>

The element counter displays the number of A/D samples that have been acquired for the element. Most of the elements are sampled at a pre-determined rate and this field can be used to determine the elapsed time between samples. This field is intended for data analysis.

The A/D samples are twelve-bit numbers representing the sample data. The A/D conversion subsystem will display the numbers in hexadecimal and will not attempt to interpret the format of the sample data.

This is intended as a development tool and should not be used during normal operation.

Notes Thermal 1.0 / 1.7x equivalents:
  • The monitor command adc stream (on <element>|off) does not have an equivalent.

Related Documents COMMAND: adc info
ERRORCODE: [00102] The sample element is invalid

Applies to: TFX THERMAL2 FB1
Access: ENG
Modified: Wed Aug 29 14:30:11 2007
Updated: Thu Jul 17 02:31:30 2008
Module: ADC