| medIndex
| media stroke to analyze
|
Analyze a single media stroke or all media strokes. The diodes are set as if the media were to be plotted. Prints a report on the accuracy of the stroke, based on the stroke targets and actual measured values.
|
|
| For each media, every diode is measured to see how far it is from the stroke target. The stroke target is the value in the media stroke at which that diode is supposed to be set. The diodes are counted and sorted, so the user can see how many achieve an accuracy of 0-1%, 1-2%, etc. Lower numbers are better.
|
|
| Option "e" displays extended information. The accuracy is printed for each diode. The accuracy value represents what percentage the actual measured value is off of the stroke target.
|
COMMAND: report
|
|
|
PARAMETER: med <media index> stroke <diode>
|
|
|
PARAMETER: med <media index> calibrate
|