Description Display a report on the health of the diodes. This command uses information from the latest power curves, so you should make sure the head was calibrated recently. This command does not turn on diodes.

The command prints the status of the diode (no curve, dead, alive) and the degredation since the head was manufactured. Degredation is measured as a percent of the original value, where positive values mean the diode is weaker.

To analyze the media stroke, use the "analyze" command.

Notes If you see a split degredation value (example: 4/-3) it means the diode has degraded in some regions of the curve, and improved on other areas! In other words, the original curve is corrupted or you have a funky diode.

Related Documents COMMAND: cal
COMMAND: analyze [<medIndex>] [e]

Applies to: TFX
Access: FIELD
Modified: Thu Nov 1 11:36:56 2001
Updated: Thu Jul 17 02:31:31 2008
Module: DPC