| bool NL
| True enables newline to be logged. Default is enabled.
|
|
| bool imaging
| True enables imaging to be logged. Default is enabled.
|
|
| trigger
| Selects the trigger index from 0 to 4. Default is 4 (imaging signal)
|
|
| sum divisor
| Selects the sum sample divisor from 1 to 65535. Default is 1.
|
|
| lpos divisor
| Selects the lpos sample divisor from 1 to 65535. Default is 1.
|
|
| error divisor
| Selects the error sample divisor from 1 to 65535. Default is 1.
|
Set up the log to collect focus data.
|
|
| Using the command with no paramters will set up the log system with the most common default values. It will trigger on Imaging and collect newline, imaging, focus sum, lens position, focus error, and focus gate information
|
|
| The possible trigger events are as follows:
|
|
|
- Automatic (0)
- Laser On (1)
- Focus On (2)
- Newline (3)
- Image (4)
|
Thermal 1.0 / 1.7x equivalents:
|
|
|
- The monitor command log focsetup does not have an equivalent.
|
COMMAND: log mode (plot|sample|off)
|
|
|
COMMAND: log stop
|
|
|
COMMAND: log trigger [<index>] [<delay>]
|
|
|
ERRORCODE: [02404] The command sequence is invalid
|
None
|