Applies to |
Note: This only applies to devices equipped with a glass encoder. |
Symptom |
|
Cause |
The LC-BP 9-pin ribbon cable runs from the backplane to the head. This cable does not have a detect loop back that checks for cable continuity, so instead the NEWLINE signal is used. If the NEWLINE signal is not detected during a plot, one or both of these errors are generated. The NEWLINE signal is generated from the index pulse on the encoder. If the device is imaging at a very low speed or if the index pulse is not detected due to a dirty encoder, the signal will not arrive as expected. |
Solution |
|
| Date submitted | 07 Apr 1999 |
| Technical contact | Jeff Edgar |