Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


I upgraded my head firmware, and now edge detect doesn't work.


Product

 

Thermal 1.0/1.7 head


Component

 

Firmware


Symptoms

 

After you upgraded your thermal head firmware, edge detect no longer works.


Cause

 

TH1.x firmware v1.85 and later uses focus overdrive during edge detect. If overdrive is not initialized correctly when you upgrade from an earlier firmware version, edge detect will not work.


Solution

 

Head firmware upgrade scripts should automatically perform the initialization. However, if the scripts fail, or if you upgrade manually, you can initialize the parameters yourself.

If you are using an MPE device, check your thermal module version first. To do this, type >> list version, and look for the line: Thermal software version. This is your thermal module version.

On MCE platforms, or MPE platforms with thermal module 4.06 or higher, type:
>> set head eover 3
>> set head eminsr 0.03

On all other MPE platforms, except the 3244 Platesetter, type:
>> mask range
>> set head r2 3000
>> set head r3 30

On the 3244 Platesetter, type:
>> mask range
>> set head bpoffset 3000
>> set head r3 30

Edge detect should now function normally.