Error 17657: DTD reset asserted occurs with error 17674 focus error, check LC-BP cable


Product

 

Devices with a Thermal 1.X head


Error

 
  • 17657 HEAD: DTD reset aserted
  • 17674 HEAD: newline error, check drum encoder and LC-BP cable (OR)focus error, check LC-BP cable

Symptoms

 

PS6 for the laser is off, because the relay K1 is not activated


Cause

 

Grounding for J27 is faulty.


Solution

 
  • Check the grounding on J27. See the schematics below.
    From the wiring diagram:
    From the BACKPLANE schematic:

Technical contact(s)
 

Jeff Edgar

Submitted by
 

Jeff Edgar

Date submitted
 

11 Oct 2006