Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Troubleshooting temperature or humidity errors


Product

 

Devices with a Thermal 1.X head


Error

 
  • 17742 HEAD: shutdown of thermal head due to temperature or humidity alarm
  • 17743 HEAD: thermal head humidity alarm, < humidity > percent

Symptoms

 

You experience one or more of the temperature or humidity errors listed above.


Cause

 

The temperature and/or humidity level in the head exceeds the setting for the nvs parameters. For more detail on temperature and humidity settings, see TH1.X Temperature and Humidity FAQ.


Solution

 
  1. Check the humidity level of the head, Type >>head status.
  2. Examine the DHU system to ensure that it has adequate airflow and a clean filter.
  3. Check that >>set head humidity is set to 30%.
    Note: If you have to adjust this value to keep a customer running, make sure there is follow up scheduled to have the DHU adjusted to bring the humidity back down to the normal range of 5 to 20%.

See also

 

TH1.X Temperature and Humidity FAQ


Technical contact(s)
 

Jeff Edgar

Submitted by
 

Jeff Edgar

Date submitted
 

07 Jun 2007