Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
Trendsetter MPE devices |
||
Component |
Devices using MPE firmware 2.55 and 2.56 with the sys wjo parameter. |
||
Symptoms |
Swaths of missing or corrupted data appear intermittently at a specified distance (defined by the wjo parameter) from the home or away edge of the plate. The width of the artifact is one swath. These two examples show the artifact on the away side. This example shows a closeup view of the artifact for greater detail. Note: the above pictures are oriented such that up = around the drum direction. |
||
Cause |
The implementation of the wjo parameter caused artifacts at the point of enabling and disabling the whisker jet. A wjo parameter of 500 would result in an artifact at 12.7 mm. |
||
Solution |
|
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
30 May 2008 |
||