| point
| Specifies the fault point from 0 to 5.
|
Display / configure the fault configuration. System faults will monitor the state of the system and if required, abort plots in progress or block the launching of plots. System faults only represent a fraction of the fault conditions that the exposure head will detect. However, other fault conditions can only be detected while a plot is in progress.
|
|
| The monitor command sys fault will display the fault configuration. The information displayed for each system fault is as follows:
|
|
| <Point> <Name> <State> <Mask>
|
|
| The system faults that will abort plots in progress or block the launching of plots are as follows:
|
|
|
- Safety Loop
- Control Board Temperature
- Focus Driver Temperature
- +5 Volts
- +3.3 Volts
- -5 Volts
- +40 Volts
- +15 Volts
- Data Cable
- Stroke Clock
|
|
| The fault state will be one of the following:
|
|
|
|
|
| The fault mask will be one of the following:
|
|
|
|
|
| The monitor command sys fault <point> (on|off) will configure the fault masks.
|
Thermal 1.0 / 1.7x equivalents:
|
|
|
- The monitor command sys fault [<point> (on|off)] is comparable to head mask (on|off) <flag>.
|
COMMAND: sys fault state
|
|
|
COMMAND: sys fault (warning|shutdown|fatal) [<number>]
|
|
|
PARAMETER: sys faultmask
|
The monitor command sys fault [<point> (on|off)] does not correspond to an API function in the CEH API document.
|