| number
| The number of warning / shutdown / fatal faults to generate.
|
Generate warning, shutdown and fatal faults to test fault handling in both the exposure head and the host.
|
|
| Warning faults do not abort the plot or shutdown the exposure head. Warning faults are returned to the host as an unsolicited warning fault.
|
|
| Shutdown faults abort the plot and shutdown the exposure head ( leaving the TEC's enabled ). Shutdown faults are returned to the host as an unsolicited fatal fault.
|
|
| Fatal faults abort the plot and shutdown the exposure head ( disabling the TEC's ). Fatal faults are returned to the host as an unsolicited fatal fault.
|
Thermal 1.0 / 1.7x equivalents:
|
|
|
- The monitor command sys fault (warning|shutdown|fatal) [<number>] does not have an equivalent.
|
COMMAND: sys fault state
|
|
|
COMMAND: sys fault [<point> (on|off)]
|
|
|
COMMAND: sys info
|
The monitor command sys fault (warning|shutdown|fatal) [<number>] does not correspond to an API function in the CEH API document.
|