Thermal 2 Errorcode: [01348] Mismatch between total focus samples/cycle and image parameters

Error details | Troubleshooting information

Thermal2 Errorcode: [01348] Mismatch between total focus samples/cycle and image parameters
Thermal2 Errorcode
[01348] Mismatch between total focus samples/cycle and image parameters

Service Information The auto-focus system counts the number of focus samples that occur during each drum rotation (or image cycle). If the measured value doesn't match the number of samples per rotation calculated based on the image parameters received by the head this error is generated.

Operator Action Call service.

Causes
  • The number of mainscan image pixels is set incorrectly.
  • The drum diameter parameter is set incorrectly.
  • The media thickness is set incorrectly.
  • The drum RPM is set incorrectly.
  • The image DPI is set incorrectly.

Applies to: TFX THERMAL2
Modified: Wed Mar 21 17:28:37 2007
Updated: Thu Jul 17 02:31:35 2008
Module: FOC