Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 2 Errorcode: [03512] The edge detect state is invalid ( on / off plate )

Error details | Troubleshooting information

Thermal2 Errorcode: [03512] The edge detect state is invalid ( on / off plate )
Thermal2 Errorcode
[03512] The edge detect state is invalid ( on / off plate )

Service Information The "Standard" edge detect control mode requires that the edge detect start off-plate and the "Featureless" edge detect control mode requires that the edge detect start on-plate. Before initiating the edge detect, the host will reset the edge detect state. This error indicates that the edge detect state is invalid for the edge detect control mode.

Operator Action Verify the loading of the plate and the plate size defined by the host.

Causes
  • The edge detect is being initiated in an invalid location.

Related Documents COMMAND: sys edge reset

Applies to: THERMAL2
Modified: Fri Apr 20 13:24:45 2007
Updated: Thu Jul 17 02:31:36 2008
Module: SYS

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.