Thermal 2 Errorcode: [03545] The stroke calibration has been aborted

Error details | Troubleshooting information

Thermal2 Errorcode: [03545] The stroke calibration has been aborted
Thermal2 Errorcode
[03545] The stroke calibration has been aborted

Service Information The commands implemented by the exposure head are non-blocking. As a result, the command to perform a stroke calibration will only initiate the stroke calibration. This error code indicates that a stroke calibration has been aborted.

Note that the command to initiate the stroke calibration can be aborted when requested by the host ( or user ) or when required by the fault handler.

Operator Action None, this is an informational message only.

Causes
  • The stroke calibration mode has been aborted.

Related Documents COMMAND: sys plot (init|start|pause|restart|stop|abort)
COMMAND: sys stroke cal state
COMMAND: sys stroke cal

Applies to: THERMAL2
Modified: Fri Apr 20 13:24:45 2007
Updated: Thu Jul 17 02:31:35 2008
Module: SYS

Troubleshooting information


Possible cause

 

This indicates failure to do a stroke cal. There are many reasons for this error, such as an error in any of the involved subsystems (LDD, BPD, and BBS).


Suggested action

 
  1. Enable verbose for LDD, BPD, and BBS.
  2. Do a stroke cal.
  3. Observe if any other error message appears with verbose enabled.
  4. Continue troubleshooting according to the new error message.