Thermal 2 Errorcode: [03802] Invalid verbose level

Error details | Troubleshooting information

Thermal2 Errorcode: [03802] Invalid verbose level
Thermal2 Errorcode
[03802] Invalid verbose level

Service Information The monitor command vbs enable (<subsytem>|all) <level> will enable the verbose level for the subsystem(s).

The verbose level consists of three masks as follows:
  • HighOp ( bit 0, value of 1 ) enables the display of high operation functions.
  • Errors ( bit 1, value of 2 ) enables the display of error translations.
  • Debug ( bit 2, value of 4 ) enables the display of general debug information.
Any combination of the three masks may be enabled.

Operator Action Verify the previous monitor command and enter a valid verbose level.

Causes
  • The verbose level is invalid.

Related Documents COMMAND: vbs enable (<subsystem>|all) <level>

Applies to: TFX THERMAL2
Modified: Wed Aug 15 16:33:48 2001
Updated: Thu Jul 17 02:31:37 2008
Module: VBS