Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


How to run LDD Calibrate

About LDD Calibrate | When to run LDD Calibrate | How to run LDD Calibrate

About LDD Calibrate

When to run LDD Calibrate

Run LDD Calibrate:

How to run LDD Calibrate

Tips:

  1. Type the following commands:
    >> Redirect enable
    TH2 > eng
    TH2 > set ldd
  2. Record the two values under LDD currentfactor. Refer to the sample code.
  3. Type the following commands:
    TH2 > bpd mode on
    TH2 > lvd mode local
    TH2 > ldd calibrate
  4. You will see the following:
    Turn on the laser (Y/N)?
    y
    Y-Intercept=5.9254 Amps, Slope=1.815 Amps/Watt
    *** Command Success ***
    The beam-pointing has settled!

    DANGER: The laser is on. Follow all laser safety procedures.
  5. Type the following commands:
    TH2 > ldd mode off
    TH2 > ldd info
    DANGER: The laser is still on at this point. Remember to turn it off.
  6. Record the active value for the parameter LDD currentfactor.

For full details on how LDD calibrate works, refer to Th2 Write Laser and LDD Calibrate: Details and Troubleshooting (PowerPoint presentation).

Contact Doug Jeffery if you have any questions.


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.