Measuring the humidity level inside a Thermal 2 Head


Product

  Thermal 2 Head

Machines affected

 

All devices with a TH2 head


Before you start

 
  • Note that the head does not generate any humidity-related error messages. If the humidity in the head is too high the head will continue to function until it fails (due to, for example, an electrical short).
  • In order to check the humidity inside a TH2 head, the head must have Head Control Board revision D or higher.

Procedure

 
  1. Verify the revision of the board. Type the following command at the TH2 prompt (in Splot or Service Shell):
    TH2 > ver

    Project: Thermal 2
    Firmware: 1.01f Release
    Build: 1780
    Date: Mar 20 2002 15:00:59
    Control board: 4
    Xilinx: 30
    *** Command Success ***


    Note: Control board number 4 = revision D, board number 3 = revision C, board number 2 = revision B, and so on.

    If the revision of the board is 3 or less, you will not be able to follow this procedure. Escalate to your regional PSS.
  2. Measure the humidity of the head. Type the following command at the TH2 prompt (in Splot or Service Shell):
    Note: Humidity is given as a voltage.
    TH2 > volt
    +40V 39.72 Volts
    +5V 4.93 Volts
    +3.3V 3.31 Volts
    -5V -4.89 Volts
    Vpp 0.00 Volts
    +15V 14.90 Volts
    Humidity 1.34 Volts
    *** Command Success ***
  3. Convert the value from Volts to a humidity level (relative humidity) using the following formula:
    Relative Humidity = [32.258 * Humidity (in Volts)] - 25.806 (at 25° Celsius)
    For example, using the voltage measurement from the sample above:
    RH = [32.258 * 1.34]-25.806 = 17.42 %

Interpreting the Results

 

Inside a TH2 head there are two separate cavities:

  • An optic cavity, containing the laser and associated imaging optics
  • A cooled electronics cavity, containing the head power supplies and controller

Each of these areas has specific environmental limitations:

  Humidity Control Risk Assessment
Optic Cavity
  • Has an airtight seal
  • Is actively desiccated

Assuming proper functionality of the air supply and internal Nafion dryer, the head is generally immune to external humidity during normal operation. The only humidity-based risk in the optic cavity is long term migration of water vapor into the optic cavity while the head is powered off or in storage.

Note: If the head is stored in very hot and humid conditions (such as 80%RH and 30°C) for over a week, then the head should be purged for several hours before the write laser is turned on. To purge the head:

  1. Hook up the head, including air lines.
  2. Turn on the system.
Electronics Cavity
  • Has a dust tight seal
  • Is actively desiccated
  • It is cooled by a passive heat exchanger

Note: The head's humidity sensor is mounted in this cavity.

  • If the system uses a passive chiller, there is no condensation risk as long as the ambient room air is non-condensing.
  • If the system uses an active chiller, there is a condensation risk only if the Nafion drying system fails.

The exact safe Relative Humidity (RH) limit is dependent on the chiller temperature. As a guideline, for chiller temperatures between 25°C and 32.5°C, the maximum allowable measured RH in the board box is ~45%


Summary

 
  • If the head has been exposed to very high humidity conditions (80% at 30°C) for over a week, then the head should be purged for several hours before the write laser is turned on.
  • For passively cooled systems, there is no humidity-related danger that can be avoided by monitoring the head's humidity sensor.
  • For actively cooled systems, the reported RH should be less than 45%RH while the chiller is operating.

Technical contact
 

Doug Jeffery

Submitted by
 
Date submitted
 

16 Dec 2003