Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


The M8 sensor is saturated


Product

 

Thermal 2 head


Error

 

[02340]: Laser power cannot be maintained due to sensor saturation


Symptoms

 

The error appears all the time. Image artifacts may occur.


Cause

 

The M8 sensor is saturated.


Solution

 
  1. Ensure that the power is set correctly and is not over the maximum supported laser power.
  2. Run M8Measure.spt and verify that the M8 sensor is saturated. See the sample results below.
  3. If the error persists and artifacts are present, determine the laser current that caused the M8 sensor to saturate. Use the results of M8Measure.spt to determine this laser current value.
  4. Temporarily reduce the laser power to below the level that saturated the M8 sensor. Order a replacement head.

See also

 

Sample M8Measure.spt results:


Technical contact(s)
 

Kyle Good

Submitted by
 

Kyle Good

Date submitted
 

30 Jan 2007


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.