Warning fault 02517 "A data overflow has been detected" occurs when the hotlink cable is disconnected


Product

 

Thermal 2 head


Component

 

Head firmware version 1.05c or later


Error

 

Warning [CEH:Warning Fault [02517] Light Valve: A data overflow has been detected]


Symptoms

 

Plates come out blank, but the job doesn't fail. Warning 02517 is generated.


Cause

 

The hotlink cable is disconnected. Firmware version 1.05c and 1.05d do not detect a disconnected hotlink cable.


Solution

 

Connect the hotlink cable properly or, if necessary, replace it.


See also

 

Thermal 2 firmware version 1.05d release notes


Technical contact(s)
 

Doug Jeffery

Submitted by
 

Frank van Eerdt

Date submitted
 

03 May 2006