Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Humidity and oil in the air supply causes banding and error 02334 Laser Power Is Unstable


Product

 

Thermal 2 head


Error

 

02334 Laser Power is Unstable


Symptoms

 

Banding, with or without error 02334 Laser Power is Unstable. The error can occur intermittently or with every plot.


Causes

  Possible causes:
  • The head has just been installed and the nafion has not been connected for long enough to drop the humidity.
  • The nafion is not connected or the nafion air line is kinked.
  • The customer air supply is contaminated with water or oil.
  • The device air filters have not been replaced recently.

Solution

 
  1. Check that the customer air supply is clean and dry. This needs to be fixed before you hook up the nafion. Note that oil can coat the nafion such that it no longer dehumidifies the head.
  2. If required, replace the device inline air filters.
  3. Check and undo any kinks or bends in the nafion air line.
  4. Connect the nafion and wait for 30 minutes.

If you still get error 02334, contact the RC. If you still see banding, continue troubleshooting.


Technical contact(s)
 

Kyle Good

Submitted by
 

Kyle Good

Date submitted
 

25 Aug 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.