Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Triangle artifact occurs on home side of plate


Product

 
  • Thermal 1.X head
  • Negative and positive media

Error

 

Typically, no errors occur with this artifact. You may see the message:
WARNING: Focus sum out of range during focus learn.


Symptoms

 

Large triangle-shaped areas on the home side of the plate are blank. See the sample plates:

 

 


Causes

 

Focus learn has fallen off the plate. It could fall off the plate due to:

  • edge detection issues
  • the GC setting has an incorrect subscan shift
  • the plate may not be square, and may be loaded crookedly
  • burrs on the plate edge

Solution

 
  1. Check the edge detection calibration.
  2. Check that the plate is loaded correctly. Confirm that the plate is square. Check the autoloader (if applicable).
  3. Check the GC setting by running a plot 100.
  4. Check for damage or defects on the plate.

Technical contact(s)
 

Kyle Good

Submitted by
 

Kyle Good

Date submitted
 

31 Aug 2006