Sample |
|||
Applies to |
Lotem Quantum |
||
Description |
Appears as a thin line at the end of the plot on the away side. The line runs in the mainscan direction (around the drum). |
||
Cause |
Some Lotem Quantums were geometrically corrected without the thermister, and with an older version of MCE firmware. When the thermister is installed and the MCE firmware is upgraded, a scaling problem results and the image becomes shorter by approximately 500 microns. |
||
Solution |
Have the GC corrected. Note that you cannot do this in the field. Refer to the Lotem Quantum Escalation page for information on how to escalate this. |
||