Thermal3 Command
(requires ENG access)
dbg clockstest

Description Performs a comparison of the relative frequencies of the clocks on the head controller board. A table is displayed showing the results of the test. If all four frequencies tested failed, then it is likely that the reference clock is out of spec. If only one frequency failed, then the indicated clock source is out of spec. A failure indicates a hardware fault with the head controller board.

Notes Thermal 1.0 / 1.7x equivalents:
  • The monitor command dbg clockstest does not have an equivalent.

Thermal 2 equivalents:
  • The monitor command dbg clockstest does not have an equivalent.

Related Documents COMMAND: dbg ddrmemtest (swath|spare)
COMMAND: dbg ethernettest
COMMAND: dbg addressbustest
ERRORCODE: [06606] The relative clock frequency test failed

Applies to: THERMAL3
Access: ENG
Modified: Wed Jul 16 04:28:30 2008
Updated: Wed Jul 16 04:52:20 2008
Module: DBG