Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [06606] The relative clock frequency test failed

Error details

Thermal3 Errorcode: [06606] The relative clock frequency test failed
Thermal3 Errorcode
[06606] The relative clock frequency test failed

Service Information An error has been detected during the test of the relative clock frequencies. If all four frequencies tested failed, then it is likely that the reference clock is out of spec. If only one frequency failed, then the indicated clock source is out of spec. A failure indicates a hardware fault with the head controller board.

Operator Action Call service.

Causes
  • Hardware fault on the head controller board.

Related Documents COMMAND: dbg clockstest

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:30 2008
Updated: Wed Jul 16 04:52:16 2008
Module: DBG

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.