Thermal3 Command
(requires ENG access)
lvd pattern <nibbles>

Variables nibbles From 1 to 116 nibbles that configure the spot pattern.

Description Initialize the spot state for all spots to the specified pattern. From 1 to 116 nibbles may be entered where each nibble will initialize the spot state of four spots ( high bit first, low bit last ). If less than 116 nibbles are present, then the specified pattern will be repeated.

Notes Thermal 1.0 / 1.7x equivalents:
  • The monitor command lvd pattern <nibbles> does not have an equivalent.
  • Thermal 1.0 / 1.7x is limited to 240 pixels.
  • Thermal 1.0 / 1.7x is limited to turning one, two or four pixels on at any time with all remaining pixels off.

Thermal 2 equivalents:
  • The monitor command lvd pattern <nibbles> is equivalent to lvd pattern <nibbles>.
  • Thermal 2 is limited to 240 pixels.

Related Documents COMMAND: lvd (<offset> <width>|all) (off|on)
COMMAND: lvd (<offset> <width>|all)
ERRORCODE: [05811] The pattern string has invalid characters
ERRORCODE: [05812] The length of the pattern string is invalid

Applies to: THERMAL3
Access: ENG
Modified: Wed Jul 16 04:28:36 2008
Updated: Wed Jul 16 04:52:20 2008
Module: LVD