|
|
|
|
| offset
| Specifies the first spot to display from 0 to 463.
|
|
| width
| Specifies the number of spots to display from 1 to 464.
|
Display state and level information for the specified range of spots. The information is displayed as follows:
|
|
| <Offset>: <State>,<Level (High)>,<Level (Low)> <State>,<Level (High)>,<Level (Low)> ...
|
|
| Each line will display information for a maximum of six spots. Thus, to display information for all spots requires seventy-eight lines.
|
|
| The spot offset is the number of the spot from 0 to 463 for the first spot in the line.
|
|
| The spot state, configurable for individual spots, will be one of the following:
|
|
|
|
|
| The spot level, which can be configured for spot quads, will range from 0 to 255. A spot level of 0 configures the maximum spot power and a spot level of 255 configures the minimum spot power.
|
|
| The spot configuration can be updated as required, but the spot state only takes affect for the "Local" light valve control modes and the spot level only takes affect for the "Plot" and "Local" light valve control modes.
|
|
| The NVS parameters med <media index> strokeoffset and med <media index> strokewidth configure the stroke. Note that the configured stroke does not affect the spot offset.
|
Thermal 1.0 / 1.7x equivalents:
|
|
|
- The monitor command lvd (<offset> <width>|all) does not have an equivalent.
|
|
| Thermal 2 equivalents:
|
|
|
- The monitor command lvd (<offset> <width>|all) is equivalent to lvd (<offset> <width>|all).
|
COMMAND: lvd (<offset> <width>|all) (off|on)
|
|
|
COMMAND: lvd (<offset> <width>|all) level (high|low) <level>
|
|
|
COMMAND: lvd pattern <nibbles>
|
|
|
ERRORCODE: [05807] The spot index is invalid
|