Thermal3 Command
(requires ENG access)
sat integrity


Description A satellite board is considered to have full integrity if:
  • The satellite is flagged as installed.
  • The satellite is detected and configured at power up.
  • The satellite has no run time fault flags currently asserted.

The output from this monitor command on a lab test jig might look like the following:

[0] NPE  ---> NPE:  power monitor fault
[1] ACT  ---> Full integrity
[2] PBP  ---> Satellite not installed
[3] IBS  ---> Satellite not installed
[4] DBP  ---> Satellite not installed
[5] WLC  ---> Satellite not installed
[6] RFE  ---> Full integrity
[7] LVDU ---> Full integrity
[8] LVDL ---> Full integrity
[9] PBP2 ---> Full integrity        
In the above example, four satellites are not installed. Of the six that are installed, five have full integrity and one has a status fault. Note that in a fully functioning production head ( i.e. a head that is not being used in a lab development scenario ), it is expected that all satellites will report full integrity.

Notes Thermal 1.0 / 1.7x equivalents:
  • The monitor command sat integrity does not have an equivalent.

Thermal 2 equivalents:
  • The monitor command sat integrity does not have an equivalent.

Related Documents COMMAND: sat ver
COMMAND: sat status
COMMAND: sat mask [(on|off) <index>]
COMMAND: sat (install|uninstall) [<satellite>]
COMMAND: sat uninstall all

Firmware Notes The satellite boards that are displayed will depend on the version of Head controller board that is in the head.

Applies to: THERMAL3
Access: ENG
Modified: Wed Jul 16 04:28:38 2008
Updated: Wed Jul 16 04:52:22 2008
Module: SAT