Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [08002] The board version is not supported

Error details

Thermal3 Errorcode: [08002] The board version is not supported
Thermal3 Errorcode
[08002] The board version is not supported

Service Information This error indicates that the currently installed actuator (ACT) board does not support the selected stepper drivers.

  • ACT board version 0 does not support any stepper drivers.
  • ACT board versions 1 and 2 support the fast shutter and automatic beam-blockers.
  • ACT board versions 3+ only support the fast shutter.

Operator Action Call service.

Causes
  • If the currently installed actuator board is version 0, then any access to the ACT subsystem will raise this error.
  • If the currently installed actuator board is version 3+, then trying to move the beam-blockers with the "act actuate" comand will raise this error.

Related Documents COMMAND: act actuate <index> <steps>
COMMAND: act info

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:28 2008
Updated: Wed Jul 16 04:52:20 2008
Module: ACT