Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [08009] The fast shutter was not open for imaging

Error details

Thermal3 Errorcode: [08009] The fast shutter was not open for imaging
Thermal3 Errorcode
[08009] The fast shutter was not open for imaging

Service Information During imaging, the fast shutter must be open. This error indicates that the fast shutter was not open for the start of the swath.

Operator Action Call service.

Causes
  • Hardware failure of the stepper driver.
  • Firmware error that will occur during firmware development and testing.

Related Documents COMMAND: act info

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:28 2008
Updated: Wed Jul 16 04:52:20 2008
Module: ACT