Thermal 3 Errorcode: [01029] Timeout waiting to learn focus

Error details

Thermal3 Errorcode: [01029] Timeout waiting to learn focus
Thermal3 Errorcode
[01029] Timeout waiting to learn focus

Service Information This error occurs when the auto focus system takes too many drum rotations to establish a plate profile table which can be tracked with minimum focus error during a 'focus learn' or a 'focus adjust' operation.

Minimum focus error is established when the error does not exceed +/-10 microns more than 10 times in a single drum rotation. This minimum focus error condition must be established within a maximum of 10 drum rotations or this error is generated. In a typical normal scenario, the focus error falls to less than 5 microns on any sample period of 100 us and remains steady within 3 drum rotations.

Operator Action Check plate loading, proper media settings, attempted imaging over clamps or other invalid plate areas.

Causes
  • Inability to establish minimal error during 'focus learn' or 'focus adjust'

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:31 2008
Updated: Wed Jul 16 04:52:19 2008
Module: FOC

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.