Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [01030] Focus Tracking Error

Error details

Thermal3 Errorcode: [01030] Focus Tracking Error
Thermal3 Errorcode
[01030] Focus Tracking Error

Service Information This 'error' is actually just a warning. It occurs if the focus tracking error exceeds +/- 10 microns on any plot. The error is sent to the host to warn the operator that image focus problems may be manifest. A tracking error of greater than 10 microns does not guarantee a focus errors. For this reason the plot is allowed to continue to avoid wasting the plate. However, the plate may need to be examined closely for focus errors.

Operator Action Examine the current plate for general image quality and focus problems.

Causes
  • Focus tracking error exceeds +/- 10 microns on the last plot

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:31 2008
Updated: Wed Jul 16 04:52:16 2008
Module: FOC

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.