Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [05209] Timeout waiting for the sample acquisition

Error details

Thermal3 Errorcode: [05209] Timeout waiting for the sample acquisition
Thermal3 Errorcode
[05209] Timeout waiting for the sample acquisition

Service Information Setup of the laser power controller, tuning of the laser power controller, etc, requires the acquisition of A/D samples from the laser diode sensor. Failure to acquire laser diode sensor samples indicates either a hardware failure or a firmware development error.

Operator Action Call service.

Causes
  • A hardware failure preventing the generation of A/D samples.
  • Firmware error that will occur during firmware development and testing.

Related Documents COMMAND: ldd sample

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:35 2008
Updated: Wed Jul 16 04:52:17 2008
Module: LDD

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.