Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [05214] The light valve mode is invalid

Error details

Thermal3 Errorcode: [05214] The light valve mode is invalid
Thermal3 Errorcode
[05214] The light valve mode is invalid

Service Information The laser diode driver will determine the state of the light valve driver. This error indicates that the control mode of the light valve driver is invalid.

Operator Action Call service.

Causes
  • The monitor command ldd cal (dual|a|b) <setpoint> requires the user to manually configure the light valve driver.
  • Attempting multiple accesses of the light valve driver ( i.e. entering monitor commands while the host is turning on the write laser ).
  • Firmware error that will occur during firmware development and testing.

Related Documents COMMAND: ldd cal (dual|a|b) <setpoint>
COMMAND: laser (on|off)

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:35 2008
Updated: Wed Jul 16 04:52:16 2008
Module: LDD