Thermal 3 Errorcode: [05207] The control mode transition is invalid

Error details

Thermal3 Errorcode: [05207] The control mode transition is invalid
Thermal3 Errorcode
[05207] The control mode transition is invalid

Service Information The monitor commands ldd on man (dual|a|b) <setpoint> and ldd man (dual|a|b) <setpoint> will set the laser diode control mode without updating the state of the beam-pointing driver. However if the laser mode is being modified, the beam-pointing driver must be updated with the laser mode. This error indicates that the requested laser diode control mode cannot be configured due to the ambiguous handling of the beam-pointing driver.

Operator Action Verify the previous monitor command and enter a valid control mode transition.

Causes
  • The requested laser diode control mode cannot be configured.

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:35 2008
Updated: Wed Jul 16 04:52:16 2008