Thermal 3 Errorcode: [04607] Invalid field table

Error details

Thermal3 Errorcode: [04607] Invalid field table
Thermal3 Errorcode
[04607] Invalid field table

Service Information All sample points must be registered with a table describing the fields of the sample / plot data. When the sample point is registered, the field table is verified. Since sample point registration is part of initialization, this error will indicate a firmware development error.

Note that the table describing the fields of the sample / plot data is verified as follows:
  • The name string must not be null and the length of the name string is limited to sixteen characters.
  • The description string must not be null and the length of the description string is limited to sixty characters.
  • The units string must not be null and the length of the units string is limited to sixteen characters.
  • The field type is verified.
  • The size of all fields must equal the sample size.

Operator Action Call service.

Causes
  • Firmware error that will occur during firmware development and testing.

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:36 2008