Thermal 3 Errorcode: [06222] FIFO underrun error, the image may be corrupt

Error details

Thermal3 Errorcode: [06222] FIFO underrun error, the image may be corrupt
Thermal3 Errorcode
[06222] FIFO underrun error, the image may be corrupt

Service Information The plot subsystem implements a swath buffer for the image data. This error indicates that the FIFO used to transfer image from the swath buffer to the light valve has underrun.

Operator Action Call service.

Causes
  • The host is attempting to image the next swath before the exposure head is ready to image the next swath.
  • The host has incorrectly configured the mainscan image size.
  • The host is generating an invalid imaging signal.

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:37 2008
Updated: Wed Jul 16 04:52:15 2008
Module: PLT