Thermal 3 Errorcode: [06218] A partial swath is still buffered, the image may be corrupt

Error details

Thermal3 Errorcode: [06218] A partial swath is still buffered, the image may be corrupt
Thermal3 Errorcode
[06218] A partial swath is still buffered, the image may be corrupt

Service Information The quantity of image data received from the host does not match the quantity of image data required for the image. As a result, a partial swath has not been imaged. Typically this will result in corruption of the image.

Specifically, the FIFO's for the light valve driver were not empty at the end of the plot.

Operator Action Call service.

Causes
  • The image data is corrupt.

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:37 2008
Updated: Wed Jul 16 04:52:18 2008
Module: PLT