Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [06221] The mainscan image size is mismatched, the image may be corrupt

Error details

Thermal3 Errorcode: [06221] The mainscan image size is mismatched, the image may be corrupt
Thermal3 Errorcode
[06221] The mainscan image size is mismatched, the image may be corrupt

Service Information A mismatch has been detected in the mainscan image size. Either the host has incorrectly configured the mainscan image size or the host is generating an invalid imaging signal.

Specifically, the exposure head has determined the mainscan image size by counting the number of SCLK's in the imaged swath and this does not match the mainscan image size that has been configured by the host.

Operator Action Call service.

Causes
  • The host has incorrectly configured the mainscan image size.
  • The host is generating an invalid imaging signal.

Related Documents COMMAND: plt mode (image|off)
COMMAND: plt info

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:37 2008
Updated: Wed Jul 16 04:52:17 2008
Module: PLT