Thermal 3 Errorcode: [06204] The synthesizer configuration is invalid

Error details

Thermal3 Errorcode: [06204] The synthesizer configuration is invalid
Thermal3 Errorcode
[06204] The synthesizer configuration is invalid

Service Information The monitor command plt synthesizer <dd> <ds> <msz> <ssz> <dpi> [invert] [overlap] will update the synthesizer configuration. This error code indicates the synthesizer configuration is invalid.

Operator Action Verify the previous monitor command and enter a valid synthesizer configuration.

Causes
  • The drum speed is 0.0 RPM.
  • The drum size is less than 1000 pixels or greater than 4,194,303 pixels.
  • The image mainscan size is less than 100 pixels or greater than 4,194,303 pixels.
  • The drum size is less than the image mainscan size.
  • The stroke clock frequency is greater than 7800.0 MHz.
  • The invert flag is invalid.
  • The overlap flag is invalid.

Related Documents COMMAND: plt synthesizer <dd> <ds> <msz> <ssz> <dpi> [invert] [overlap]