Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [06205] The TPG configuration is invalid

Error details

Thermal3 Errorcode: [06205] The TPG configuration is invalid
Thermal3 Errorcode
[06205] The TPG configuration is invalid

Service Information The monitor command plt tpg <msz> <dpi> [invert] [overlap] will update the TPG configuration. This error code indicates the TPG configuration is invalid.

Operator Action Verify the previous monitor command and enter a valid TPG configuration.

Causes
  • The image mainscan size is less than 100 pixels or greater than 4,194,303 pixels.
  • The invert flag is invalid.
  • The overlap flag is invalid.

Related Documents COMMAND: plt tpg <msz> <dpi> [invert] [overlap]

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:37 2008
Updated: Wed Jul 16 04:52:17 2008
Module: PLT

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.