Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [05642] Warning fault(s) have been discarded

Error details

Thermal3 Errorcode: [05642] Warning fault(s) have been discarded
Thermal3 Errorcode
[05642] Warning fault(s) have been discarded

Service Information Due to insufficient bandwidth of the datalink between the exposure head and the host, all of the warning fault(s) could not be reported to the host. The exposure head will perform all necessary internal handling for the warning fault(s) and then discard the warning fault(s).

Note that a shutdown or fatal fault has not been discarded.

Operator Action None, this is an informational message only.

Causes
  • Warning fault(s) have been discarded by the exposure head.

Related Documents ERRORCODE: [05643] Fatal fault(s) have been discarded

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:39 2008
Updated: Wed Jul 16 04:52:18 2008
Module: SYS