Thermal 3 Errorcode: [05618] Failure reading the system parameter

Error details

Thermal3 Errorcode: [05618] Failure reading the system parameter
Thermal3 Errorcode
[05618] Failure reading the system parameter

Service Information System parameters are the parameters in the exposure head that the host can read and / or write.

When the host reads a system parameter, the exposure head will read the system parameter as required. This error code indicates that the NVS parameter corresponding to the system parameter could not be read.

Due to limitations of the Thermal 1.0 / 1.7x interface, the number of error codes that can be returned to the host are limited. Enabling the error translation level for the system subsystem will display a more specific error.

Operator Action Call service.

Causes
  • Corruption of the registry.
  • Firmware error that will occur during firmware development and testing.

Related Documents COMMAND: reg verify [baseline]
COMMAND: sys parm access <index> (disable|enable)
COMMAND: sys parm [<index> <value>]
COMMAND: vbs enable (<subsystem>|all) <level>

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:39 2008
Updated: Wed Jul 16 04:52:16 2008
Module: SYS