Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [05620] Failure verifying the system parameters

Error details

Thermal3 Errorcode: [05620] Failure verifying the system parameters
Thermal3 Errorcode
[05620] Failure verifying the system parameters

Service Information System parameters are the parameters in the exposure head that the host can read and / or write.

Normally when the host writes a system parameter, the exposure head will write the system parameter as required. However, to prevent constant updates of the the exposure head, the exposure head is only updated if the system parameter has been modified. This error code indicates that a failure occured determining the present state of the exposure head.

Due to limitations of the Thermal 1.0 / 1.7x interface, the number of error codes that can be returned to the host are limited. Enabling the error translation level for the system subsystem will display a more specific error.

Operator Action Call service.

Causes
  • Corruption of the registry.
  • Firmware error that will occur during firmware development and testing.

Related Documents COMMAND: reg verify [baseline]
COMMAND: vbs enable (<subsystem>|all) <level>

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:39 2008
Updated: Wed Jul 16 04:52:18 2008
Module: SYS

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.