Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [03402] Invalid verbose level

Error details

Thermal3 Errorcode: [03402] Invalid verbose level
Thermal3 Errorcode
[03402] Invalid verbose level

Service Information The monitor command vbs enable (<subsystem>|all) <level> will enable the verbose level for the subsystem(s).

The verbose level consists of four masks as follows:
  • HighOp ( bit 0, value of 1 ) enables the display of high operation functions.
  • Errors ( bit 1, value of 2 ) enables the display of error translations.
  • Debug ( bit 2, value of 4 ) enables the display of general debug information.
  • State ( bit 3, value of 8 ) enables the display of state machine information.
Any combination of the four masks may be enabled.

Operator Action Verify the previous monitor command and enter a valid verbose level.

Causes
  • The verbose level is invalid.

Related Documents COMMAND: vbs enable (<subsystem>|all) <level>

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:48 2008
Updated: Wed Jul 16 04:52:19 2008
Module: VBS

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.