Thermal3 Parameter
(requires ENG access)
lvd blockerwidth

Description The NVS parameters med <media index> strokeoffset and med <media index> strokewidth configure the pixels that will be used for plotting. The NVS parameters lvd blockeroffset and lvd blockerwidth configure the pixels that are not physically blocked. The NVS parameter lvd blockerwidth determines the number of pixels that have not been physically blocked.

There are several requirements for the stroke configuration as follows:
  • The offset and width of the configured stroke must be a multiple of eight.
  • The configured stroke must not exceed the maximum number of pixels.
  • The configured stroke must not be phsyically blocked.

Type Integer

Default Value 448

Range 8 to 464

Related Documents PARAMETER: med <media index> strokeoffset
PARAMETER: med <media index> strokewidth
PARAMETER: lvd blockeroffset

Applies to: THERMAL3
Access: ENG
Modified: Wed Jul 16 04:28:36 2008
Updated: Wed Jul 16 04:52:23 2008
Module: LVD